CABLETRON-TRAPS DEFINITIONS ::= BEGIN

        --  cabletron-traps.txt
        --  Revision: 01.04.03
        --  Part Number:  2170994
        --  Date: January 10, 1999

        --  Date        "200402061530Z"  - Fri Feb  6 15:30 GMT 2004
        --  Added boardOperational and boardNonOperational traps.

        -- "Postal:  Enterasys Networks
        --           50 Minuteman Rd.
        --           Andover, MA 01810-1008
        --           USA
        --  Phone:   +1 978 684 1000
        --  E-mail:  support@enterasys.com
        --  WWW:     http://www.enterasys.com"

        --  This module provides authoritative definitions for Cabletron's
        --  use of IETF and enterprise-specific snmp traps.
        --
        --  This module will be extended, as required.
        --

        --  Enterasys Networks reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Enterasys Networks
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Enterasys Networks be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Enterasys 
        --  Networks has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Enterasys grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this specification in connection
        --  with the management of Enterasys products.

        --  Copyright (c)1998 Cabletron Systems
        --  Copyright (c)2004 Enterasys Networks

--  ---------------------
--  Top Level Definitions
--  ---------------------

-- Imports

IMPORTS
        cabletron
                        FROM CTRON-OIDS
        TRAP-TYPE
                        FROM RFC-1215
        ifIndex
                        FROM RFC1213-MIB

        logEventIndex, logIndex, logTime, logDescription
                        FROM RFC1271-MIB

        lecRowStatus    FROM LAN-EMULATION-CLIENT-MIB

        fddimibSMTIndex, fddimibPORTIndex, fddimibMACIndex, fddimibSMTCFState,
        fddimibPORTConnectState, fddimibSMTMasterCts, fddimibPORTAction,
        fddimibPORTLerEstimate, fddimibMACRMTState, fddimibMACCurrentPath,
        fddimibMACFrameErrorRatio 
                        FROM FDDI-SMT73-MIB     -- rfc1512

        ctsmtmibRingTopology, ctsmtmibRingSmtIndex, ctsmtmibRingMacIndex,
        ctsmtmibRingNodeIndex, ctsmtmibRingMacAddr
                        FROM CTSMTMIB-MIB

        nwAppnFwdLsAdjCpName, nwAppnFwdLsAdjCpType,
        nwAppnFwdLsName, nwAppnEventTextString
                        FROM CTRON-APPN-MIB

        nwAtEventTextString
                        FROM CTRON-AppleTalk-ROUTER-MIB

        snmpPollDestination, snmpPollOwner, snmpOIDDestination,
        snmpOIDOwner, snmpOIDSequence, snmpOIDObject
                        FROM DLM-MIB
        bdgdeviceStatus
                        FROM CTRON-BDG-MIB

        rptrSrcAddrMgmtPortLock, rptrPortAlarmBroadThreshold,
        rptrMgmtInterfaceNum, rptrAlarmsTrafThreshold, 
        rptrAlarmsErrThreshold, rptrAlarmsErrSource, 
        rptrAlarmsCollThreshold, rptrPortGrpAlarmBroadThreshold, 
        rptrAlarmsBroadThreshold, rptrAlarmsAlarmTimebase, 
        rptrPortGrpMgmtGrpId, rptrPortGrpAlarmTrafThreshold, 
        rptrPortGrpAlarmErrThreshold, rptrPortGrpAlarmErrSource, 
        rptrPortGrpAlarmCollThreshold, rptrPortSecurityLockStatus,
        rptrPortMgmtPortType, rptrPortMgmtPortId, 
        rptrPortRedundCrctNum, rptrPortSrcAddrTopoState, 
        rptrPortSrcAddrAddressList, rptrPortAlarmTrafThreshold, 
        rptrPortAlarmErrThreshold, rptrPortAlarmErrSource, 
        rptrPortAlarmCollThreshold,  rptrPortSecurityPortGrpId,
        rptrPortSecurityPortId, rptrPortSecuritySecureState,
        rptrSecurityLearnState, rptrPortGrpSrcAddrLockGrpId,
        rptrPortGrpSASecurityLearnState, 
        rptrPortSecurityLearnState, rptrSecurityLearnMode,
        rptrPortGrpSASecurityLearnMode,
        rptrPortSecurityLearnMode
                        FROM REPEATER-REV4-MIB

        chSlotID, chSlotModuleType
                        FROM CHASSIS-MIB

        powerSupplyNum, deviceType 
                        FROM CTRON-COMMON-MIB

        ctFpRedundActivePort
                        FROM CTRON-FRONTPANEL-MIB

        nwIpEventTextString
                        FROM CTRON-IP-ROUTER-MIB

        nwIpxEventTextString
                        FROM CTRON-IPX-ROUTER-MIB

        nwDecIVEventTextString
                        FROM CTRON-DECIV-ROUTER-MIB


        ctIfNumber, ctIfPortPortNumber, ctIfPortType
                        FROM CTIF-EXT-MIB

        psPowerSlotStatusID, boardPowerSlotStatusID, psPowerSlotID,
        chPowerMainVoltageStatus, chPowerMainVoltage, 
        chPowerDiagVoltageStatus, chPowerDiagVoltage, termPowerStatus,
        termPowerVoltage, boardPowerSlotID, boardPowerID, 
        boardPowerStatus, termPowerModule1Status, termPowerModule2Status,
        boardPowerCurrent, boardPowerLocalAdminStatus, boardPowerLocalStatus,
        boardPowerOperationalStatus, psPowerID, psPowerOperationalStatus,
        psPowerAdmin, psPowerCurrent, psPowerStatus, psPowerVoltage,
        boardPowerVoltage, chPowerLineMaxSupply, chPowerLineTotalSupply 
                        FROM CTRON-POWER-SUPPLY-MIB
     
        psEnvFanStatus, psEnvSlotID, psEnvFanSpeed, psEnvTemp,
        psEnvTempStatus, chEnvFanSpeed, chEnvFanStatus, chEnvFanID,
        chEnvAmbientStatus, chEnvAmbientTemp, chEnvHumidityStatus,
        chEnvHumidity, boardEnvSlotID, boardEnvTemp, boardEnvTempStatus,
        boardEnvTempRelStatus 
                        FROM  CTRON-ENVIRONMENT-MIB

        contTypePhysicalChanges, contTypeLogicalChanges, 
        contPhysicalEntryID
                        FROM CT-CONTAINER-MIB
                           
        tRingAlarmsRingRingPurgesThreshold, 
        tRingStatsRingLastBeaconType,
        tRingAlarmsRingTimebase,
        tRingAlarmsRingAMPErrsThreshold, 
        tRingAlarmsRingTokenErrsThreshold,
        tRingAlarmsRingClaimTknThreshold, 
        tRingAlarmsRingLostFramesThreshold,
        tRingAlarmsRingBeaconStateThreshold, 
        tRingAlarmsRingFrameCountThreshold,
        tRingAlarmsStnThrshLineErrsThreshold,
        tRingAlarmsStnThrshInternalErrsThreshold, 
        tRingAlarmsStnThrshBurstErrsThreshold,
        tRingAlarmsStnThrshACErrsThreshold,
        tRingAlarmsStnThrshRcvrCongestThreshold, 
        tRingAlarmsStnThrshAddress,
        tRingMgmtStnName,tRingMgmtStnBoard,
        tRingMgmtStnPort,tRingMgmtStnUNA,
        tRingMgmtSecurityAddressAdd,
        tRingMgmtSecurityAddressRemove,
        tRingStatsRingLastBeacon, tRingMgmtStnAddress,
        tRingPortMgmtPortId, tRingPortGrpId,
        tRingMgmtStnDNA
                        FROM DOT5-LOG-MIB

        ctATMPhyRedundIfIndex
                        FROM CTATM-CONFIG-MIB

        ctBroadcastDesiredBroadcastThreshold, ctBroadcastCtlSlotID,
        ctBroadcastCtlInterface
                        FROM CT-BROADCAST-MIB

        ctChasPowerSupplyNum, ctChasPowerSupplyType
                        FROM CTRON-CHASSIS-MIB

        upsIndex, upsStatusFault, upsExtMeasAlarmStatus,
        upsAddlFuncsStatusFault
                        FROM UPS2-MIB

        atmInterfaceMyNeighborIpAddress,
        atmInterfaceMyNeighborIfName,atmVpCrossConnectRowStatus,
        atmVcCrossConnectRowStatus
                        FROM ATM-MIB

        sfpsNodeTablePort,sfpsNodeTableBaseAddress
                        FROM CTRON-SFPS-DIRECTORY-MIB

        sfpsDirViolationType, sfpsDirViolationAOValue
                        FROM CTRON-SFPS-TOPOLOGY-MIB

        sfpsInPortConfigType, sfpsInPortConfigPort
                        FROM CTRON-SFPS-PORT-MIB
        sfpsBlockResolveTableAOValue
                        FROM CTRON-SFPS-RESOLVE-MIB
        sfpsBlockSourceMAC
                        FROM CTRON-SFPS-BASE-MIB;

-- ===================================================================

--
--  Cabletron`s Enterprise Trap Definitions
--

    ctdlswTConnUp TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is sent each time a transport connection
                    becomes enabled on this DLSw."
            ::= 1
 
    ctdlswTConnDown TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is sent each time a transport connection
                    becomes disabled on this DLSw."
            ::= 2


    portSegmenting TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId }
            DESCRIPTION
                    "When a port goes from operational to segmented, a
                    trap will be generated.  For these purposes, the
                    port state will be sampled every XXX seconds, thus
                    it will be statistically possible to miss oscillating
                    circuits."
            ::= 257 -- 0x0101

    portUnsegementing TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId }
            DESCRIPTION
                    "When it is detected that a previously segmented port
                    has gone operational, a trap will be generated.  This
                    is also sampled, thus a trap may not be generated for
                    each transition."
            ::= 258 -- 0x0102



    portLinkUp TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap will be generated when it is determined
                    that a MAU has been attached to the MMAC.  This is
                    only appropriate for MIMs that support the concept
                    of a link state."
            ::= 259 -- 0x0103

    portLinkDown TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap will be generated when a previously attached
                    MAU is removed or powered down.  Again, this is only
                    appropriate for MIM's that support link state."
            ::= 260 -- 0x0104

    srcaddrNew TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortSrcAddrAddressList }
            DESCRIPTION
                    "This trap will be generated when the MMAC detects
                    the existence of a new source address on one of it's
                    ports."
            ::= 261 -- 0x0105

    srcaddrTimeout TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortSrcAddrAddressList }
            DESCRIPTION
                    "This trap will indicate that the MMAC has not
                    detected a packet generated by this source address
                    within a certain timeout."
            ::= 262 -- 0x0106

    boardRemoval TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID }
            DESCRIPTION
                    "This trap will be generated when the MMAC detects
                    that a MIM has been removed."
            ::= 263 -- 0x0107

    boardInsertion TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID,
                      deviceType }
            DESCRIPTION
                    "This trap will generated when the MMAC determines
                    that a new board has been inserted."
            ::= 264 -- 0x0108


     redundActivePortInCircuitFailed TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortRedundCrctNum }
            DESCRIPTION
                    "This trap will be generated when the active port in
                    a redundant circuit has failed polling.  This will
                    indicate the activation of redundancy."
            ::= 265 -- 0x0109

    redundPortActivated TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortRedundCrctNum }
            DESCRIPTION
                    "This trap indicates that a new port has been
                    activated in a redundant circuit.  This does NOT
                    indicate that this port is usable, but is being
                    tested.  If the port fails, a failure trap (above)
                    will be generated."
            ::= 266 -- 0x010A

    redundPortTestFailed TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortRedundCrctNum }
            DESCRIPTION
                    "This trap will be generated when the MMAC executes
                    it's periodic redundancy diagnostics and finds one
                    of the ports in a redundant circuit has failed.
                    This message will not indicate that redundancy has
                    been activated, just that the port has failed and
                    should be fixed before it is needed."
            ::= 267 -- 0x010B

 
    boardTrafficThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpAlarmTrafThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId }
            DESCRIPTION
                    "This trap will be generated when the traffic (good
                    packets per time interval) has been exceeded for a
                    particular MIM."
            ::= 271 -- 0x010F


    boardErrorThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpAlarmErrThreshold,
                      rptrPortGrpAlarmErrSource,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId }
             DESCRIPTION
                    "This trap will be generated when packets of the
                    selected error type exceeds a threshold percentage of
                    the good packets for a particular interval for a
                    particular MIM."
            ::= 272 -- 0x0110


    boardCollsionThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpAlarmCollThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId }
            DESCRIPTION
                    "This trap will be generated when collisions exceed a
                    threshold percentage of the good packets for a particular
                    interval for a particular MIM."
            ::= 273 -- 0x0111


    portTrafficThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortAlarmTrafThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap will be generated when the traffic (good
                    packets per time interval) has been exceeded for a
                    particular port."
            ::= 274 -- 0x0112


    portErrorThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortAlarmErrThreshold,
                      rptrPortAlarmErrSource,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap will be generated when packets of the
                    selected error type exceeds a threshold percentage of
                    the good packets for a particular interval for a
                    particular port."
            ::= 275 -- 0x0113


    portCollsionThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortAlarmCollThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap will be generated when collisions exceed a
                    threshold percentage of the good packets for a particular
                    interval for a particular port."
            ::= 276 -- 0x0114


    portTypeChanged TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId,
                      rptrPortSrcAddrTopoState }
            DESCRIPTION
                    "This trap indicates that a port has changed from a
                    station port to a trunk port or vice versa."
            ::= 277 -- 0x0115

    portSecurityViolation TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId,
                      rptrPortSrcAddrAddressList }

            DESCRIPTION
                    "This trap is generated when a source address other
                    than those locked to a port is seen."
            ::= 279 -- 0x0117

    portViolationReset TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap is generated when management intervention
                    has reset a port after a violation has occurred."
            ::= 280 -- 0x0118

    envTempWarm TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID }
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the temperature within a MIM has reached a WARM
                    condition."
            ::= 281 -- 0x0119

    envTempHot TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID }
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the temperature within a MIM has reached a HOT
                    condition."
            ::= 282 -- 0x011A

    envVoltageLow TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { powerSupplyNum }
            DESCRIPTION
                    "This trap is generated when a power supply's voltage
                    is LOW."
            ::= 283 -- 0x011B

    envTempNormal TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID }
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the temperature within a MIM has returned to a
                    NORMAL state."
            ::= 284 -- 0x011C


    envVoltageNormal TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when all power supplies' voltage
                    have returned to a NORMAL state."
            ::= 285 -- 0x011D


    fanFail TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the system fans have failed."
            ::= 286 -- 0x011E
    
    fanNormal TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the system fans have returned to normal."
            ::= 287 -- 0x011F

    
    boardBroadcastThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpAlarmBroadThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId }
            DESCRIPTION
                    "This trap is generated when the broadcast packets
                    (per time interval) have exceeded the threshold for
                    the given board."
            ::= 289 -- 0x0121


    portBroadcastThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortAlarmBroadThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap is generated when the broadcast packets
                    (per time interval) have exceeded the threshold for
                    the given port."
            ::= 290 -- 0x0122

    systemVoltageLow TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the power to the EMME is low."
            ::= 293 -- 0x0125    

    systemVoltageNormal TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the device detects that
                    the power to the EMME has returned to normal."
            ::= 294 -- 0x0126


    epimRemoval TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap is generated when it is detected that an
                    EPIM has been removed."
            ::= 295 -- 0x0127

    epimInsertion TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES   { rptrPortGrpMgmtGrpId,
                        rptrPortMgmtPortId,
                        rptrPortMgmtPortType }
            DESCRIPTION
                    "This trap is generated when it is detected that an
                    EPIM has been inserted."
            ::= 296 -- 0x0128


    rptrTrafficThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrAlarmsTrafThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrMgmtInterfaceNum }
            DESCRIPTION
                    "This trap will be generated when the traffic (good
                    packets per time interval) has been exceeded for a
                    network."
            ::= 297 -- 0x0129


    rptrErrorThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrAlarmsErrThreshold,
                      rptrAlarmsErrSource,
                      rptrAlarmsAlarmTimebase,
                      rptrMgmtInterfaceNum }
            DESCRIPTION
                    "This trap will be generated when packets of the
                    selected error type exceeds a threshold percentage of
                    the good packets for a particular interval for an
                    entire network."
            ::= 304 -- 0x0130


    rptrCollsionThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrAlarmsCollThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrMgmtInterfaceNum }
            DESCRIPTION
                    "This trap will be generated when collisions exceed a
                    threshold percentage of the good packets for a particular
                    interval for an entire network."
            ::= 305 -- 0x0131


    rptrLockStatusChanged TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrSrcAddrMgmtPortLock,
                      rptrMgmtInterfaceNum }
            DESCRIPTION
                    "This trap is generated when the status of the address
                    lock changes for a certain network."
            ::= 306 -- 0x0132

     rptrBroadcastThresholdExceeded TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrAlarmsBroadThreshold,
                      rptrAlarmsAlarmTimebase,
                      rptrMgmtInterfaceNum }
            DESCRIPTION
                        "This trap is generated when the broadcast packets 
                        (per time interval) have exceeded the threshold for 
                        the given repeater."
            ::= 307 -- 0x0133


     srcAddressPortLockStatusChange TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortGrpMgmtGrpId,
                      rptrPortMgmtPortId,
                      rptrPortSecurityLockStatus }
            DESCRIPTION
                        "This trap is generated when a change to the 
                        source address locking is detected at the port level."
            ::= 309 -- 0x0135

    chBoardInsertion TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { chSlotID,
                      chSlotModuleType }
            DESCRIPTION
                    "This trap will generated when the MMAC determines
                    that a new board has been inserted."
            ::= 310 -- 0x0136

        portSecureStateChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrPortSecurityPortGrpId,
                rptrPortSecurityPortId,
                rptrPortSecuritySecureState}
        DESCRIPTION
                "This trap is generated when the status of the secure state
                changes for a specific port."
        ::= 313         -- 0x139


        rptrLearnStateChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrMgmtInterfaceNum,
                rptrSecurityLearnState }
        DESCRIPTION
                "This trap is generated when network learning is reset.  
                When learning is reset, all secure addresses on each 
                port, within the network, will be deleted and ports will 
                learn source addresses, again."
        ::= 314         -- 0x13A
   
        rptrPortGrpLearnStateChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrPortGrpSrcAddrLockGrpId,
                rptrPortGrpSASecurityLearnState }
        DESCRIPTION
                "This trap is generated when port group learning is reset.  
                When learning is reset, all secure addresses on each port, 
                within the port group, will be deleted and ports will learn 
                source addresses, again."
        ::= 315         -- 0x13B 

        rptrPortLearnStateChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrPortSecurityPortGrpId,
                rptrPortSecurityPortId,
                rptrPortSecurityLearnState }
        DESCRIPTION
                "This trap is generated when learning on a port is reset.  
                When learning is reset, all secure addresses on the port 
                will be deleted and the port will learn source addresses, 
                again."
        ::= 316         -- 0x13C 

        rptrLearnModeChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrMgmtInterfaceNum,
                rptrSecurityLearnMode }
        DESCRIPTION
                "This trap is generated when network learn mode is
                changed between one-time learn mode and continuous 
                learn mode."
        ::= 317         -- 0x13D 

        portGrpLearnModeChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrPortGrpSrcAddrLockGrpId,
                rptrPortGrpSASecurityLearnMode }
        DESCRIPTION
                "This trap is generated when the port group learn 
                mode is changed between one-time learn mode and 
                continuous learn mode."
        ::= 318         -- 0x13E 

        portLearnModeChanged TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { rptrPortSecurityPortGrpId,
                rptrPortSecurityPortId,
                rptrPortSecurityLearnMode }
        DESCRIPTION
                "This trap is generated when the port learn 
                mode is changed between one-time learn mode and 
                continuous learn mode."
        ::= 319         -- 0x13F



    fpportActivated TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { rptrPortMgmtPortId }
            DESCRIPTION
                    "This trap is generated when a port is activated in
                    redundancy due to another port failing."
            ::= 400 -- 0x0190


        interfacePortInsertion TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { ctIfNumber, ctIfPortPortNumber, ctIfPortType }
            DESCRIPTION
                "This trap  will be generated when it is detected that an
                interface port has been inserted."
        ::= 416 -- 0x1A0


        interfacePortRemoval TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { ctIfNumber, ctIfPortPortNumber }
            DESCRIPTION
                "This trap  will be generated when it is detected that an
                interface port has been removed."
        ::= 417 -- 0x1A1

        interfacePortLinkUp TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { ctIfNumber, ctIfPortPortNumber }
            DESCRIPTION
                "This trap will be generated when it is determined that
                a port on a strictly bridging interface (not a 'repeater')
                has been connected to a LAN. This is only appropriate
         for ports that support the concept of a link state."
        ::= 418 -- 0x1A2

        interfacePortLinkDown TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { ctIfNumber, ctIfPortPortNumber }
            DESCRIPTION
                "This trap will be generated when a previously attached
                bridging port has been disconnected from a LAN. This is
                only appropriate for ports that support the concept of a
                link state."
        ::= 419 -- 0x1A3

    portInserted TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a stations port's link state
                    turns on while the management state of the port is
                    Enabled."
            ::= 513 -- 0x0201

    portDeInserted TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a stations port's link state
                    turns off while the management state of the port is
                    Enabled."
            ::= 514 -- 0x0202


    ringSpeedFault TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId }
            DESCRIPTION
                    "This trap is sent when a board enters the ring speed
                    fault state due to a station or ring port attaching
                    to the board as a different speed than the board is
                    configured for."
            ::= 515 -- 0x0203

    ringSpeedFaultCleared TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId }
            DESCRIPTION
                    "This trap is sent when a board leaves the ring
                    speed fault state."
            ::= 516 -- 0x0204


    ringPortFaulted TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a ring port wraps when its
                    management state is Active, without regard for the
                    selected type of the ring port."
            ::= 517 -- 0x0205

    ringPortFaultCleared TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a ring port unwraps when its
                    management state is Active, without regard for the
                    selected type of the ring port."
            ::= 518 -- 0x0206


    beaconState TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingStatsRingLastBeaconType,
                      tRingMgmtStnName,
                      tRingMgmtStnUNA,
                      tRingMgmtStnBoard,
                      tRingMgmtStnPort }
            DESCRIPTION
                    "This trap occurs when a Beacon is detected on the
                    ring while the ring is in the Operational state, or
                    when the Beacon contains different information than
                    the last Beacon received."
            ::= 519 -- 0x0207

    beaconStateCleared TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingStatsRingLastBeacon }
            DESCRIPTION
                    "This trap occurs when a ring returns to the
                    Operational state."
            ::= 520 -- 0x0208


    stationAdded TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingMgmtSecurityAddressAdd }
            DESCRIPTION
                    "This trap is sent when a new station address is
                    added to the security allowed list"
            ::= 521 -- 0x0209


    stationRemoved TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingMgmtSecurityAddressRemove }
            DESCRIPTION
                    "This trap is sent when a station is rejected
                     from the ring with a REMOVE MAC command sent
                     by the ring security."
            ::= 522 -- 0x020a


    ringConfigurationChanged TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is sent when the TRMM has built a
                    new station map."
            ::= 523 -- 0x020B

    faultRecoveryPortRemoved TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent after a fault recovery condition
                    has been corrected, and reports that a port was
                    removed in the process of correcting the condition."
            ::= 524 -- 0x020C


    faultRecoveryBoardBypassed TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId }
            DESCRIPTION
                    "This trap is sent after a fault recovery condition
                    has been corrected, and reports that a board was
                    bypassed in the process of correcting the condition."
            ::= 525 -- 0x020D


    portViolation TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a port link state turns on
                    and the port's management state is Disabled."
            ::= 526 -- 0x020E

    portViolationCleared TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingPortGrpId,
                      tRingPortMgmtPortId }
            DESCRIPTION
                    "This trap is sent when a port link state turns off
                    and the port's management state is Disabled."
            ::= 527 -- 0x020F



    faultRecoveryOscillation TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is sent when the ring has oscillated several
                    times within a short amount of time.  The ring is
                    considered oscillating if it has failed a short time
                    after recovering."
            ::= 528 -- 0x0210

    ringPurgeThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingRingPurgesThreshold,
                    tRingAlarmsRingTimebase }
            DESCRIPTION
                "This trap is sent when ring purge errors have exceeded
                the specified threshold value."
            ::= 529 -- 0x0211


    amErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingAMPErrsThreshold,
                      tRingAlarmsRingTimebase }
            DESCRIPTION
                "This trap is sent when Active Monitor errors have exceeded
                the specified threshold value."
            ::= 530 -- 0x0212


    tokenErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingTokenErrsThreshold,
                      tRingAlarmsRingTimebase }
            DESCRIPTION
                    "This trap is sent when Token errors have exceeded
                    the specified threshold value."
            ::= 531 -- 0x0213


    claimTokenThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingClaimTknThreshold,
                      tRingAlarmsRingTimebase  }
            DESCRIPTION
                "This trap is sent when claim tokens have exceeded
                the specified threshold value."
            ::= 532 -- 0x0214


    lostFramesThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingLostFramesThreshold,
                      tRingAlarmsRingTimebase }
            DESCRIPTION
                "This trap is sent when the Lost Frame count has exceeded
                the specified threshold value."
            ::= 533 -- 0x0215


    beaconStateThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingBeaconStateThreshold,
                      tRingAlarmsRingTimebase }
            DESCRIPTION
                "This trap is sent when the Beacon State count has exceeded
                the specified threshold value."
            ::= 534 -- 0x0216


    frameCountThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsRingFrameCountThreshold,
                      tRingAlarmsRingTimebase }
            DESCRIPTION
                "This trap is sent when the frame count has exceeded
                the specified threshold value."
            ::= 535 -- 0x0217


    lineErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsStnThrshLineErrsThreshold,
                      tRingAlarmsRingTimebase,
                      tRingAlarmsStnThrshAddress }
            DESCRIPTION
                "This trap is sent when the line errors have exceeded
                the specified threshold value for the station."
            ::= 536 -- 0x0218


    internalErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsStnThrshInternalErrsThreshold,
                      tRingAlarmsRingTimebase,
                      tRingAlarmsStnThrshAddress }
            DESCRIPTION
                "This trap is sent when the Lost internal errors have exceeded
                the specified threshold value for the station."
            ::= 537 -- 0x0219


    burstErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsStnThrshBurstErrsThreshold,
                      tRingAlarmsRingTimebase,
                      tRingAlarmsStnThrshAddress }
            DESCRIPTION
                "This trap is sent when the Lost burst errors have exceeded
                the specified threshold value for the station."
            ::= 538 -- 0x021A


    acErrorsThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsStnThrshACErrsThreshold,
                      tRingAlarmsRingTimebase,
                      tRingAlarmsStnThrshAddress }
            DESCRIPTION
                "This trap is sent when address/copied errors have exceeded
                the specified threshold value for the station."
            ::= 539 -- 0x021B


    receiverCongestionThreshold TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingAlarmsStnThrshRcvrCongestThreshold,
                      tRingAlarmsRingTimebase,
                      tRingAlarmsStnThrshAddress }
            DESCRIPTION
                "This trap is sent when receiver congestion errors have exceeded
                the specified threshold value for the station."
            ::= 540 -- 0x021C


    removeStationFailure TRAP-TYPE
--      STATUS  deprecated
            ENTERPRISE cabletron
            VARIABLES { tRingMgmtSecurityAddressRemove }
            DESCRIPTION
                    "This trap is sent when a station breaks through security
                    and cannot be removed from the ring."
            ::= 541 -- 0x021D

        ringSpeedPortFault      TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE  cabletron
            VARIABLES { tRingPortGrpId, tRingPortMgmtPortId }
            DESCRIPTION
                "This  trap is generated when a port enters the ring speed
                fault state due to a station or ring port attaching to the
                port at a different speed than the port is configured for."
            ::= 542     -- 0x21E

        ringSpeedPortFaultCleared       TRAP-TYPE
--          STATUS      deprecated
            ENTERPRISE  cabletron
            VARIABLES { tRingPortGrpId, tRingPortMgmtPortId }
            DESCRIPTION
                "This  trap is generated when a port leaves the ring speed
                fault state."
            ::= 543     -- 0x21F

        stnPortInserted TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID, 
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a stations port's link state
                turns on while the management state of the port is
                Enabled."
        ::= 544 -- 0x0220

        stnPortDeInserted TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a stations port's link state
                turns off while the management state of the port is
                Enabled."
        ::= 545 -- 0x0221

        boardRingSpeedFault TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID}
        DESCRIPTION
                "This trap is sent when a 'active NON-93 series' board
                enters the ring speed fault state due to a station or ring
                port attaching to the board as a different speed than the
                board is configured for."
        ::= 546 -- 0x0222

        boardRingSpeedFaultCleared TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID}
        DESCRIPTION
                "This trap is sent when a board leaves the ring
                speed fault state."
        ::= 547 -- 0x0223

        ringPortWrapped TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID, 
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a ring port wraps when its
                management state is Active, without regard for the
                selected type of the ring port."
        ::= 548 -- 0x0224

        ringPortWrapCleared TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a ring port unwraps when its
                management state is Active, without regard for the
                selected type of the ring port."
        ::= 549 -- 0x225


        beaconingState TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                  tRingMgmtStnName,
                  tRingMgmtStnAddress,
                  tRingMgmtStnUNA,
                  tRingMgmtStnBoard,
                  tRingPortGrpId,
                  tRingMgmtStnPort,
                  tRingStatsRingLastBeaconType }
        DESCRIPTION
            "This trap occurs, if beacon recovery is enabled,
            when Beaconing, Ring Purging or Claim Tokens are detected 
            on the ring while the ring is in the Operational state, or
            when the Beacon contains different information than
            the last Beacon received."
        ::= 550 -- 0x0226

        beaconingStateCleared TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex, 
                tRingStatsRingLastBeacon }
        DESCRIPTION
            "This trap occurs when a ring returns to the
            Operational state."
        ::= 551 -- 0x0227

        stnAdded        TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { ifIndex, tRingMgmtSecurityAddressAdd }
        DESCRIPTION
                "This trap is sent when a new station is added to the
                security allowed list."
        ::= 552 -- 0x0228

        stnRemoved TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingMgmtSecurityAddressRemove }
        DESCRIPTION
        "This trap is sent when a station is rejected
        from the ring with a REMOVE MAC command sent
        by the ring security."
        ::= 553 -- 0x0229

        removeStnFailure TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingMgmtSecurityAddressRemove }
        DESCRIPTION
                "This trap is sent when a station breaks through security
                and cannot be removed from the ring."
        ::= 554 -- 0x022A
        

        ringSecurityPortRemoved  TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
        "This trap is sent when a ring security break
        has been corrected, and reports that a port was
        removed (disabled) in the process of correcting the condition."
        ::= 555 -- 0x022B

        beaconRecoveryPortRemoved TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent after a fault recovery condition
                has been corrected, and reports that a port was
                removed in the process of correcting the condition."
        ::= 556 -- 0x022C


        beaconRecoveryPortGroupBypassed TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,tRingPortGrpId }
        DESCRIPTION
                "This trap is sent after a fault recovery condition
                has been corrected, and reports that a port group was
                bypassed in the process of correcting the condition."
        ::= 557 -- 0x022D

        beaconRecoveryBoardBypassed TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID }
        DESCRIPTION
                "This trap is sent after a fault recovery condition
                has been corrected, and reports that a board was
                bypassed in the process of correcting the condition."
        ::= 558 -- 0x022E

        portLinkViolation TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a port link state turns on
                and the port's management state is Disabled."
        ::= 559 -- 0x022F

        portLinkViolationCleared TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId,
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is sent when a port link state turns off
                and the port's management state is Disabled."
        ::= 560 -- 0x0230

        ringPurgeTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingRingPurgesThreshold,
                tRingAlarmsRingTimebase }
        DESCRIPTION
                "This trap is sent when ring purge errors have exceeded
                the specified threshold value."
        ::= 561 -- 0x0231


        amErrorsTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingAMPErrsThreshold,
                tRingAlarmsRingTimebase }
        DESCRIPTION
                "This trap is sent when Active Monitor errors have exceeded
                the specified threshold value."
        ::= 562 -- 0x0232


        tokenErrorsTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingTokenErrsThreshold,
                tRingAlarmsRingTimebase }
        DESCRIPTION
                "This trap is sent when Token errors have exceeded
                the specified threshold value."
        ::= 563 -- 0x0233


        claimTokenTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingClaimTknThreshold,
                tRingAlarmsRingTimebase  }
        DESCRIPTION
                "This trap is sent when claim tokens have exceeded
                the specified threshold value."
        ::= 564 -- 0x0234

        lostFramesTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingLostFramesThreshold,
                tRingAlarmsRingTimebase }
        DESCRIPTION
                "This trap is sent when the Lost Frame count has exceeded
                the specified threshold value."
        ::= 565 -- 0x0235

        frameCountTotalThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsRingFrameCountThreshold,
                tRingAlarmsRingTimebase }
        DESCRIPTION
                "This trap is sent when the frame count has exceeded
                the specified threshold value."
        ::= 566 -- 0x0236


        lineErrorsStnThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsStnThrshLineErrsThreshold,
                tRingAlarmsRingTimebase,
                tRingAlarmsStnThrshAddress }
        DESCRIPTION
                "This trap is sent when the line errors have exceeded
                the specified threshold value for the station."
        ::= 567 -- 0x0237


        internalErrorsStnThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsStnThrshInternalErrsThreshold,
                tRingAlarmsRingTimebase,
                tRingAlarmsStnThrshAddress }
        DESCRIPTION
                "This trap is sent when the Lost internal errors have exceeded
                the specified threshold value for the station."
        ::= 568 -- 0x0238


        burstErrorsStnThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsStnThrshBurstErrsThreshold,
                tRingAlarmsRingTimebase,
                tRingAlarmsStnThrshAddress }
        DESCRIPTION
                "This trap is sent when the Lost burst errors have exceeded
                the specified threshold value for the station."
        ::= 569 -- 0x0239


        acErrorsStnThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsStnThrshACErrsThreshold,
                tRingAlarmsRingTimebase,
                tRingAlarmsStnThrshAddress }
        DESCRIPTION
                "This trap is sent when address/copied errors have exceeded
                the specified threshold value for the station."
        ::= 570 -- 0x023A


        receiverCongestionStnThreshold TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex,
                tRingAlarmsStnThrshRcvrCongestThreshold,
                tRingAlarmsRingTimebase,
                tRingAlarmsStnThrshAddress }
        DESCRIPTION
                "This trap is sent when receiver congestion errors have exceeded
                the specified threshold value for the station."
        ::= 571 -- 0x023B


        ringSpeedPortFaulted    TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES { chSlotID, 
                tRingPortGrpId, 
                tRingPortMgmtPortId }
        DESCRIPTION
                "This  trap is generated when a port enters the ring speed
                fault state due to a station or ring port attaching to the
                port at a different speed than the port is configured for."
        ::= 572 -- 0x023C


        ringSpeedPortFaultedCleared     TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId, 
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is generated when a port leaves the ring speed
                fault state."
        ::= 573 -- 0x023D


        tpimInserted TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId, 
                tRingPortMgmtPortId }
        DESCRIPTION
                "This trap is generated when a TPIM is installed."
        ::= 574 -- 0x023E

        tpimRemoved TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES { chSlotID,
                tRingPortGrpId, 
                tRingPortMgmtPortId }
        DESCRIPTION
                "This  trap is generated when a TPIM is removed."
        ::= 575 -- 0x023F

        neighborNotificationInc TRAP-TYPE             
        ENTERPRISE cabletron
        VARIABLES { ifIndex }
        DESCRIPTION
                "This trap is sent each time the neighbor notification (ring
                poll) does not complete."
        ::= 576 -- 0x0240

        fltRecoveryOscillation TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { ifIndex }
        DESCRIPTION
                "This trap is sent when the ring has oscillated (in 
                and out of beaconing) when beacon recovery is enabled. 
                The ring is considered oscillating if it has 
                failed 21 secs after recovering from the previous."
        ::= 577 -- 0x0241

    ringPollFailureEventCorrected  TRAP-TYPE             
    ENTERPRISE cabletron
    VARIABLES { ifIndex,
        tRingMgmtStnAddress,
        tRingMgmtStnDNA,
        tRingMgmtStnBoard,
        tRingMgmtStnPort }
    DESCRIPTION
        "This trap is sent after the management  module successfully
        recovered the Ring Poll Failure condition."
    ::= 578 -- 0x0242

    ringPollFailureEventNotCorrected  TRAP-TYPE             
    ENTERPRISE cabletron
    VARIABLES { ifIndex,  
        tRingMgmtStnAddress }
    DESCRIPTION
        "This trap is sent after the management module has failed to
        recover the Ring Poll Failure condition.  The interesting
        information includes the interface number and the MAC address
        of the last successful ring poll station."
    ::= 579 -- 0x0243

    sPVP  TRAP-TYPE
    ENTERPRISE cabletron
--  VARIABLES { spvpAtmAddress,
--      timeStamp,
--      releaseCause }
    DESCRIPTION
        "This trap indicates that a SPVP was rerouted. 
        The variables indicates the address of a rerouted spvp, the time 
        stamp of when rerouting occurred, and the cause of rerouting. 
        The cause codes are as follows: 
        Unallocated (unassigned) number = 1 
        No route to specified transit network = 2 
        No route to destination = 3 
        Normal call clearing = 16
        User busy = 17
        No user responding = 18
        Call rejected = 21
        Number changed = 22
        User rejects all calls with calling line
                                identification restriction (CLIR) = 23
        Destination out of order = 27
        Invalid number format (address incomplete) = 28
        Response to STATUS ENQUIRY = 30
        Normal, unspecified = 31
        Requested VPCI/VCI not available = 35
        VPCI/VCI assignment failure = 36
        User cell rate not available = 37
        Network out of order = 38
                        Temporary failure = 41
        Access information discarded = 43
        No VPCI/VCI available = 45
        Resource unavailable, unspecified = 47
        Quality of Service unavailable = 49
        Bearer capability not authorized = 57
        Bearer capability not presently available = 58
        Service or option not available, unspecified = 63
        Bearer capability not implemented = 65
        Unsupported combination of traffic parameters = 73
        AAL parameters cannot be supported = 78
        Invalid call reference value = 81
        Identified channel does not exist = 82
        Incompatible destination = 88
        Invalid endpoint reference = 89
        Invalid transit network selection = 91
        Too many pending add party requests = 92
        Mandatory information element missing = 96
        Message type non-existent or not implemented = 97
        Information element non existent or not implemented = 99
        Invalid information element contents = 100
        Message not compatible with call state = 101
        Recovery on timer expiry = 102
        Incorrect message length = 104
        Protocol error, unspecified = 111"
    ::= 580 -- 0x0244 

    sPVC  TRAP-TYPE             
    ENTERPRISE cabletron 
--  VARIABLES { spvcAtmAddress,  
--      timeStamp,
--      releaseCause } 
    DESCRIPTION 
        "This trap indicates that a SPVC was rerouted. 
        The variables indicates the address of a rerouted spvc, the time 
        stamp of when rerouting occurred, and the cause of rerouting. 
        The cause codes are as follows: 
        Unallocated (unassigned) number = 1 
        No route to specified transit network = 2 
        No route to destination = 3 
        Normal call clearing = 16
        User busy = 17
        No user responding = 18
        Call rejected = 21
        Number changed = 22
        User rejects all calls with calling line identification
                                                restriction (CLIR) = 23
        Destination out of order = 27
        Invalid number format (address incomplete) = 28
        Response to STATUS ENQUIRY = 30
        Normal, unspecified = 31
        Requested VPCI/VCI not available = 35
        VPCI/VCI assignment failure = 36
        User cell rate not available = 37
        Network out of order = 38
        Temporary failure = 41
        Access information discarded = 43
        No VPCI/VCI available = 45
        Resource unavailable, unspecified = 47
        Quality of Service unavailable = 49
        Bearer capability not authorized = 57
        Bearer capability not presently available = 58
        Service or option not available, unspecified = 63
        Bearer capability not implemented = 65
        Unsupported combination of traffic parameters = 73
        AAL parameters cannot be supported = 78
        Invalid call reference value = 81
        Identified channel does not exist = 82
        Incompatible destination = 88
        Invalid endpoint reference = 89
        Invalid transit network selection = 91
        Too many pending add party requests = 92
        Mandatory information element missing = 96
        Message type non-existent or not implemented = 97
        Information element non existent or not implemented = 99
        Invalid information element contents = 100
        Message not compatible with call state = 101
        Recovery on timer expiry = 102
        Incorrect message length = 104
        Protocol error, unspecified = 111"
    ::= 581 -- 0x0245

--    deviceNotResponding TRAP-TYPE
--          ENTERPRISE cabletron
--          VARIABLES {  }
--          DESCRIPTION
--                  "  "
--          ::= 700  0x02BC


--    deviceConnected TRAP-TYPE
--          ENTERPRISE cabletron
--          VARIABLES {  }
--          DESCRIPTION
--                  "  "
--          ::= 701  0x02BD


--    deviceStatusUnknown TRAP-TYPE
--          ENTERPRISE cabletron
--          VARIABLES {  }
--          DESCRIPTION
--                  "  "
--          ::= 702  0x02BE

    deviceDiagnosticMessage TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated for diagnostic purposes."
            ::= 703  -- 0x02BF


    bridgeStatusChanged TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { bdgdeviceStatus }
            DESCRIPTION
                    "This trap is generated when the status of the bridge
                     changes."
            ::= 769 -- 0x0301

    aquiredDatabaseFull TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the acquired portion of
                    the bridge's filtering database is full."
            ::= 770 -- 0x0302

boardPortActivate TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES   { ctFpRedundActivePort }
        DESCRIPTION
                "This Trap is generated when Front Panel Redundancy
                 changes the active port." 
        ::= 849 -- 0x0351

boardNightVision  TRAP-TYPE
        ENTERPRISE cabletron
        DESCRIPTION
                "This trap is generated when night vision turns off or
                on.  If power to the device is lost, this trap is sent
                with a value of 0, indicating that power has been lost
                but the device is running on 'night vision'. If power 
                is not restored within 10 minutes, the device shuts down
                completely.  If power is restored in that time frame,
                the trap is sent with a value of 1 indicating as such."
        ::= 900 -- 0x384        
                
snmpLostContact TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { snmpPollDestination, snmpPollOwner }
        DESCRIPTION
                "A LostContact signifies that a the Cabletron hub has lost
                contact with the destination IP address host/device.  This trap
                is only sent at the 'trap-wait' intervals.  Note that this trap
                indicates a poll failure, not a threshold failure.  Threshold
                alarms are generated independently.  The snmpPollDestination
                indicates the lost device."
        ::= 1000 -- 0x03E8

snmpThresholdTrap TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { snmpOIDDestination, snmpOIDOwner, snmpOIDSequence, 
                    snmpOIDObject }
        DESCRIPTION
                "This trap signifies that an OID value/threshold comparison
                has failed.  The snmpOIDObject specifies which Object Identifier
                and instance (destination IP address, owner IP address, and
                sequence number) was used to trigger the alarm condition.   The 
                snmpOIDDestination indicates the node address that failed the
                OID poll."
        ::= 1001

snmpReestabContact TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { snmpPollDestination, snmpPollOwner }
        DESCRIPTION
                "A ReestabContact signifies that a the Cabletron hub has 
                reestablished contact with the destination IP address
                host/device.  This trap is sent immediately after contact 
                has been reestablished." 
        ::= 1002 -- 0x03EA

-- There are a other traps associated with ctBroadcast at 289 and 290.

ctBroadcastThresholdReached  TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { ctBroadcastDesiredBroadcastThreshold,
                      ctBroadcastCtlSlotID,
                      ctBroadcastCtlInterface}
            DESCRIPTION
                    "This trap is generated when the configured
                    broadcast threshold on a port is reached and
                    will include the slot number and port number
                    the threshold was reached on."
            ::= 1003 -- 0x03EB

ctLecStatus TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { lecRowStatus }
            DESCRIPTION
                    "This trap is generated when the operational
                    state of the LAN Emulation Client has changed."
            ::= 1004 -- 0x03EC

    fddiPortConnectStateChange  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibPORTIndex, 
                        fddimibPORTConnectState }
        DESCRIPTION
                "This trap is generated for FDDI port connection state
                changes.  The variables are found in IETF FDDI MIB
                RFC-1512."
        ::= 1024        --  0x400

    fddiSMTMasterPortIncrease   TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibSMTMasterCts }
        DESCRIPTION
                "This trap is generated whenever there is an increase in
                the number of SMT master ports."
        ::= 1025        -- 0x401

    fddiSMTMasterPortDecrease   TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibSMTMasterCts }
        DESCRIPTION
                "This trap is generated anytime there is a decrease in
                the number of SMT master ports."
        ::= 1026        -- 0x402


    fddiPortAction  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibPORTIndex, 
                        fddimibPORTAction }
        DESCRIPTION
                "This trap is generated for every action against a
                FDDI port.  The variables are found in IETF FDDI MIB
                RFC-1512."
        ::= 1027        --  0x403

    fddiPortLerAlarm  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibPORTIndex,
                        fddimibPORTLerEstimate }
        DESCRIPTION
                "This trap is generated when the long term link
                error rate, fddimibPORTLerEstimate, crosses the
                fddimibPORTLerAlarm threshold.  The variables are
                found in IETF FDDI MIB RFC-1512."
        ::= 1028        --  0x404

    fddiModuleFNBbypassed  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { chSlotID }
        DESCRIPTION
                "This trap is generated when a FDDI module
                is bypassed on the FNB."
        ::= 1030        --  0x406

    fddiModuleFNBinserted  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { chSlotID }
        DESCRIPTION
                "This trap is generated when a FDDI module
                is inserted on the FNB."
        ::= 1031        --  0x407

    fddiMACRMTState  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibMACIndex, 
                        fddimibMACRMTState }
        DESCRIPTION
                "This trap is generated when there is a
                change in the FDDI ring state.  The variables
                are found in IETF FDDI MIB RFC-1512."
        ::= 1032        --  0x408

    fddiMACCurrentPath  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibMACIndex,
                        fddimibMACCurrentPath }
        DESCRIPTION
                "This trap is generated when there is a
                change in the insertion of the MAC to the
                FDDI ring.  The variables are found in IETF
                FDDI MIB RFC-1512."
        ::= 1033        --  0x409

    fddiSMTCFState  TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibSMTCFState }
        DESCRIPTION
                "This trap is generated when there is a
                change in the attachment configuration for
                the station or concentrator.  The variables
                are found in IETF FDDI MIB RFC-1512."
        ::= 1034        --  0x40A

    fddiRingTopology TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { ctsmtmibRingSmtIndex, ctsmtmibRingMacIndex,
                        ctsmtmibRingNodeIndex, ctsmtmibRingMacAddr, 
                        ctsmtmibRingTopology }
        DESCRIPTION
                "This trap is generated when there is a
                change in the attachment configuration for
                the station or concentrator.  It provides
                information additional to fddiSMTCFState,
                twisted ring conditions in particular.  The
                variables are found in the Cabletron SMT MIB."
        ::= 1035        --  0x40B

    fddiMACFrameErrorRatio TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibMACIndex, 
                        fddimibMACFrameErrorRatio }
        DESCRIPTION
                "This trap is generated when the frame error
                ratio exceeds the frame error threshold,
                fddimibMACFrameErrorThreshold.  The variables
                are found in IETF FDDI MIB RFC-1512."
        ::= 1036        --  0x40C

    fddiMACDuplicateMACAddress TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { fddimibSMTIndex, fddimibMACIndex }
        DESCRIPTION
                "This trap is generated when the SMT detects
                a duplicate MAC address on the ring."
        ::= 1037        --  0x40D

--================== The end of the list of FDDI Traps ======================== 

--========================== container traps ==================================

    contLogicalChangesTrap TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { contTypeLogicalChanges }
        DESCRIPTION
                    "This trap is generated when any change occurs
            in the contLogicalEntryTable group of the container MIB."
            ::= 1200
 
 
    contPhysicalChangesTrap TRAP-TYPE
            ENTERPRISE cabletron
            VARIABLES { contTypePhysicalChanges }
        DESCRIPTION
                    "This trap is generated when any change occurs to
            contPhysicalEntryTable group of the container MIB."
            ::= 1201

--=============================================================================

    rtrIpEventLogChange TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { nwIpEventTextString }
        DESCRIPTION
                "This trap is generated for changes to IP event log."
        ::= 1280        -- 0x500

    rtrIPXEventLogChange        TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { nwIpxEventTextString }
        DESCRIPTION
                "This trap is generated whenever an entry is made to the
                router IPX event log for where nwIpEventSeverity has a
                value of highest(1)."
        ::= 1281        -- 0x501

    rtrDecIVEventLogChange      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { nwDecIVEventTextString }
        DESCRIPTION
                "This trap is generated whenever an entry is made to the
                router Dec Net IV event log."
        ::= 1282        -- 0x502

    rtrAppleEventLogChange      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { nwAtEventTextString }
        DESCRIPTION
                "This trap is generated whenever an entry is made to the
                router Apple Talk event log."
        ::= 1283        -- 0x503

    rtrAppnEventLogChange       TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { nwAppnEventTextString }
        DESCRIPTION
                "This trap is generated whenever an entry is made to the
                router APPN event log."
        ::= 1284        -- 0x504

nwAppnLsUp TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES   { nwAppnFwdLsName }
        DESCRIPTION
                "When a link station becomes active, a trap is
                 generated. nwAppnFwdLsName identifies the link
                 station name."
        ::= 1285        -- 0x505

nwAppnLsDown TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES       { nwAppnFwdLsName, nwAppnFwdLsAdjCpName,
                         nwAppnFwdLsAdjCpType }
        DESCRIPTION
                "When a link station is deactivated, a trap is
                 generated. nwAppnFwdLsName identifies the link
                 station name, nwAppnFwdLsAdjCpName identifies the
                 fully qualified CP name of the adjacent node and
                 nwAppnFwdLsAdjCpType is the type of that node."
        ::= 1286        -- 0x506

--      All traps between 0x578 (1400) and 0x5DB (1499) are reserved
--      for secure fast switching

-- SecureFast Traps [Trap Ids 1400 - 1499 (0578h - 05DBh)]

-- SecureFast Traps are by default Disabled.  To Enable SecureFast Traps, 
-- the "service.trap" element in the Bindery must be enabled.  In addition,
-- Individual SecureFast Traps can be disabled via the SFPSTrapAPI Mib.  
-- (Disabling a Trap is Persistant, therefore next reboot, the trap will 
-- stay disabled).  The SFPSTrap Mib can be used to view the current 
-- OperStatus of the individual traps, as well as how many of each trap 
-- have been sent, and when the last one was sent.

-- Below - <h> = Hash Value; <i> = Index Value; <p> = Port


-- Trap #1400 - New User
--
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.5.1.1.5.<h>.<i> = [Int] Port Number
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.5.1.1.7.<h>.<i> = [Str] Node's Mac Address

sfpsNewUser      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { sfpsNodeTablePort, sfpsNodeTableBaseAddress }
        DESCRIPTION
                 "This trap is generated when a new user enters the SFPS 
                  fabric."
        ::= 1400       -- 0x578
                                                  

-- Trap #1401 - Directory Violation
--
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.15.1.1.1.3.<h>.<i> = [Int] Violation Type
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.15.1.1.1.6.<h>.<i> = [Str] L2/L3 Address Value

sfpsDirectoryViolation      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { sfpsDirViolationType,sfpsDirViolationAOValue }
        DESCRIPTION
                 "This trap is generated when one of 6 violation types have occurred.
                        1 UserLock
                        2 RestrictedPort
                        3 IPNotLearned
                        4 IPInvalid
                        5 RestrictedMobility
                        6 UserLockSamePort      "
         ::= 1401       -- 0x579
                                                  

-- Trap #1402 - Source Blocked
--
-- 1.3.6.1.4.1.52.4.2.4.2.2.14.2.1.1.2.<i> = [Str] Source Mac Address Blocked

sfpsSourceBlocked      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { sfpsBlockSourceMAC }
        DESCRIPTION
                 "This trap is generated when a user (source MAC address)  has
                  surpassed the Source Blocker thresholds and is being blocked from
                  sending traffic on the network."
         ::= 1402       -- 0x57A
                                                  

-- Trap #1403 - Flood Suppressed
--
-- 1.3.6.1.4.1.52.4.2.4.2.2.2.4.1.4.1.1.4.<h>.<i> = [Str] L2/L3 Address Blocked

sfpsFloodSurpressed      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { sfpsBlockResolveTableAOValue }
        DESCRIPTION
                 "A destination address has been unresolvable past the thresholds
                  and is now being flood suppressed (only 1 per X seconds will pass)."
         ::= 1403       -- 0x57B
                                                  

-- Trap #1404 - Port to Standby
--
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.1.<p> = [Int] Port Number
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.5.<p> = [Int] New Port State

sfpsPortToStandby      TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { sfpsInPortConfigPort, sfpsInPortConfigType }
        DESCRIPTION
                 "This trap is generated when a port has entered standby.
                 There are different standby states:
                 9      STAND_BY (manually set)
                 14     STAND_BY_FCL (one way neighbor)
                 15     STAND_BY_LOOPED (self originated Hello seen on port)
                 16     STAND_BY_RTA (redundant access port is standby/backup  "
        ::= 1404       -- 0x57C


-- Trap #1405 - Port from Standby
--
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.1.<p> = [Int] Port Number
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.5.<p> = [Int] New Port State
 
 sfpsPortFromStandby      TRAP-TYPE
         ENTERPRISE      cabletron
         VARIABLES       { sfpsInPortConfigPort, sfpsInPortConfigType }
         DESCRIPTION
                  "This trap is generated when a port that was in standby is
                  now not in standby. Most common is that either a one-way 
                  neighbor situation is gone or a standby RA port is now primary."
            ::= 1405       -- 0x57D

-- ======================================================================

--      All traps between 0x600 (1536) and 0x6FF (1791) are reserved
--      for mid level managers.


    nmsMapAdded TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has added a new map to its database."
        ::= 1536

    nmsMapDeleted TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has deleted a map from its database."
        ::= 1537

    nmsMapChanged TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has changed an attribute of a map
                in its database."
        ::= 1538

    nmsMapOpened TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has opened a map."
        ::= 1539

    nmsMapClosed TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has closed a map."
        ::= 1540

    nmsElementAdded TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has added a new element to its database."
        ::= 1541

    nmsElementDeleted TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has deleted an element from its
                database."
        ::= 1542

    nmsElementChanged TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has changed an attribute of an element
                in its database."
        ::= 1543

    nmsSymbolAdded TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has added a new symbol to its database."
        ::= 1544

    nmsSymbolDeleted TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has deleted a symbol from its database."
        ::= 1545

    nmsSymbolChanged TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { logEventIndex,
                        logIndex,
                        logTime,
                        logDescription }
        DESCRIPTION
                "This trap is generated when the SOS Gateway agent detects
                that a third party NMS has changed an attribute of a symbol
                in its database."
        ::= 1546

-- ======================================================================

--      All traps between 0x708 (1800) and 0x76C (1900) are reserved
--      for the 5 Slot Work Group chassis.

    wgPsInstalled TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { ctChasPowerSupplyNum,
                          ctChasPowerSupplyType }
        DESCRIPTION
                "This trap is generated when the device detects that the
                 power supply has been installed."
        ::= 1800

    wgPsRemoved TRAP-TYPE
        ENTERPRISE      cabletron
        VARIABLES       { ctChasPowerSupplyNum }
        DESCRIPTION    
                "This trap is generated when the device detects that the 
                power supply has been removed."
        ::= 1801

    wgPsNormal TRAP-TYPE  
        ENTERPRISE      cabletron 
        VARIABLES       { ctChasPowerSupplyNum } 
        DESCRIPTION     
                "This trap is generated when the device detects that the power 
                supply has returned to normal."
        ::= 1802 

    wgPsFail TRAP-TYPE  
        ENTERPRISE      cabletron 
        VARIABLES       { ctChasPowerSupplyNum } 
        DESCRIPTION     
                "This trap is generated when the device detects that the power 
                supply has failed."
        ::= 1803 
    
    wgPsRedundant TRAP-TYPE  
        ENTERPRISE      cabletron 
        VARIABLES       { ctChasPowerSupplyNum } 
        DESCRIPTION     
                "This trap is generated when the device detects that the power
                supply is in the redundant state."
        ::= 1804 
 
    
    wgPsNotRedundant TRAP-TYPE  
        ENTERPRISE      cabletron 
        VARIABLES       { ctChasPowerSupplyNum } 
        DESCRIPTION     
                "This trap is generated when the device detects that the power 
                supply is not in the redundant state."
        ::= 1805 

    wgBoardInserted TRAP-TYPE
        ENTERPRISE     cabletron
        VARIABLES      { contPhysicalEntryID }
        DESCRIPTION
                "This trap is generated when a module is inserted."
        ::= 1806

     wgBoardRemoved TRAP-TYPE
        ENTERPRISE     cabletron
        VARIABLES      { contPhysicalEntryID }
        DESCRIPTION
                "This trap is generated when a module is removed."
        ::= 1807

 
-- ======================================================================

    aPCLineFail TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated in the event of an AC
                     utility line failure"
            ::= 4353 -- 0x1101


    aPCLineFailRecovery TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the UPS switches back
                    to line, and only if the aPCLineFail trap was issued
                    first"
            ::= 4354 -- 0x1102


    aPCLowBattery TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated in the event that the UPS'
                    battery is found to be low"
            ::= 4355 -- 0x1103


    aPCLowBatteryRecovery TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the UPS' battery has
                     charged above the low-battery point, and only if the 
                     aPCLowBattery trap was issued first"
            ::= 4356 -- 0x1104


    aPCAbnormalCondition TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated in the event that the UPS
                    has entered an abnormal condition, such as an 
                    overload or trip on low battery.  This trap is also
                    sent, when the UPS is first turned on."
            ::= 4357 -- 0x1105


    aPCAbnormConditionRecovery TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated when the UPS has recovered
                    from an abnormal condition, and only if the
                    aPCAbnormalCondition trap was issued first"
            ::= 4358 -- 0x1106


    aPCShuttingDown TRAP-TYPE
            ENTERPRISE cabletron
            DESCRIPTION
                    "This trap is generated in the event that the UPS
                    has been ordered to shut itself, or the load, off
                    over the serial line."
            ::= 4359 -- 0x1107

-- =====================================================================
--      The range of trap IDs from 5001 to 5400 decimal are reserved
--      for WAN traps.
-- ======================================================================
--      The range of trap IDs from 11001 to 11999 decimal are reserved
--      for MMAC+ traps.

emTermOverVoltage TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the term power bus is over voltage."
    ::= 11001

emTermUnderVoltage TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the term power bus is under voltage."
    ::= 11002

emTermNormalVoltage TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the term power bus is at an acceptable
        voltage. It will only be sent out after a trap was sent to say that
        the term voltage was under or over."
    ::= 11003

chHotTemp TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated because the chassis is hot."
    ::= 11004

chWarmTemp TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated because the chassis is warm."
    ::= 11005

chCoolTemp TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated because the chassis is cool."
    ::= 11006

chColdTemp TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated because the chassis is cold."
    ::= 11007

chTempOK TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated because the chassis has returned to normal
        after being warm, hot, cool or cold."
    ::= 11008

chTempSensorBroken TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis's temperature sensor is
        broken."
     ::= 11009

chHumidityStaticRisk TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis determines there is a
        humidity static risk."
    ::= 11010

chHumidityNormal TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis determines the humidity
        has returned to normal after being moist or static risk."
    ::= 11011

chHumidityMoist TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis determines there is a
        humidity moist risk."
    ::= 11012

chHumiditySensorBroken TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis determines the humidity
        sensor is broken."
    ::= 11013

chMod1INBInstalled TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination has been installed
        for module 1."
    ::= 11014

chMod1INBFaulty TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination is faulty for
        module 1."
    ::= 11015

chMod1INBRemoved TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination has been removed for
        module 1."
    ::= 11016

chMod1INBNormal TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination (module 1) has
        returned to normal after already sending a trap to say it was faulty."
    ::= 11017

chMod2INBInstalled TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination has been installed
        for module 2."
    ::= 11018

chMod2INBFaulty TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination is faulty for
        module 2."
    ::= 11019

chMod2INBRemoved TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination has been removed for
        module 2."
    ::= 11020

chMod2INBNormal TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the INV termination (module 2) has
        returned to normal after already sending a trap to say it was faulty."
    ::= 11021

emFanFailure TRAP-TYPE
    ENTERPRISE  cabletron
    DESCRIPTION
        "This trap is generated when the chassis detects a fan failure."
    ::= 11022

boardHotTempShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board is hot and the board has shut 
        itself down."
    ::= 11023

boardWarmTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board is warm."
    ::= 11024

boardCoolTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board is cool."
    ::= 11025

boardColdTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board is cold."
    ::= 11026

boardTempOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board has returned to normal after 
        being warm or hot."
    ::= 11027

boardTempSensorBroken TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the board's temperature sensor is
        broken."
    ::= 11028

boardTempHotNoAdmin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board is hot."
    ::= 11029

boardRelWarmTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp is warm."
    ::= 11030

boardRelTempOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp has returned 
        to normal after being warm or hot."
    ::= 11031

boardRelTempHotNoAdmin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp is hot but it
        cannot shutdown. It will need to be turned off remotely."
    ::= 11032

boardRelTempHotShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the board's relative temperature is hot 
        and is being powered off."
    ::= 11033

boardRelWarmTempMaxFans TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp is warm. The
        fans are on MAX."
    ::= 11034

boardRelTempOKMaxFans TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp has returned 
        to normal after being warm or hot. The fans are on MAX."
    ::= 11035

boardRelTempHotNoAdminMaxFans TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board's relative temp is hot but it
        cannot shutdown. It will need to be turned off remotely. The fans are
        on MAX."
    ::= 11036

boardRelTempHotShutdownMaxFans TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the board's relative temperature is hot 
        and is being powered off. The fans are on MAX."
    ::= 11037

boardInputVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a boards input voltage is over max."
    ::= 11038

boardInputVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a boards input voltage is under
        minimum."
    ::= 11039

boardInputVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board input voltage has returned to 
        normal after being over or under."
    ::= 11040

boardOutputVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board output voltage is over MAX."
    ::= 11041

boardOutputVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board output voltage is under MIN."
    ::= 11042

boardOutputVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board output voltage has returned to 
        normal after being over or under."
    ::= 11043

boardAuxVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a boards auxiliary voltage is over
        MAX."
    ::= 11044

boardAuxVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board auxiliary voltage is under
        MIN."
    ::= 11045

boardAuxVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board auxiliary voltage has returned 
        to normal after being over or under."
    ::= 11046

boardInputCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board input current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11047

boardOutputCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a boards output current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11048

boardInputCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board input current is 
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11049

boardOutputCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because a board output current is
        over MAX. The ability of the power supply to turn itself off has been
        disabled therefore outside intervention is needed."
    ::= 11050

boardRemotePowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board is being powered
        off due to outside intervention."
    ::= 11051

boardRemotePowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board is being powered
        on due to outside intervention."
    ::= 11052

boardRemotePowerReset TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board is being reset due to
        outside intervention."
    ::= 11053

boardPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board power has been powered on."
    ::= 11054

boardPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board power has been powered off."
    ::= 11055

boardPowerReset TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been reset."
    ::= 11056

boardRemOverCurrentShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been shutdown remotely 
        due to being over current."
    ::= 11057

boardRemPowerConservationShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been shutdown remotely 
        due to power conservation."
    ::= 11058

boardRemTemperatureShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been shutdown remotely 
        due to it's temperature."
    ::= 11059

boardReqFPDisableDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has had an unauthorized
        front panel disable."
    ::= 11060

boardFPDisableDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been disabled through
        the front panel."
    ::= 11061

boardReqFPEnableDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has had an unauthorized
        front panel enable."
    ::= 11062

boardFPEnableDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been enabled through the
        front panel."
    ::= 11063

boardReqFPResetDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has had an unauthorized
        front panel reset."
    ::= 11064

boardFPResetDCDC TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board has been reset through the 
        front panel."
    ::= 11065

boardADConvertorFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board's A/D converter is broken."
    ::= 11066

boardPICFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of a board PIC failure."
    ::= 11067

boardPICOk TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board PIC is now OK.
        This trap will only be sent AFTER a PIC failure trap has been
        generated."
    ::= 11068

boardLLAPDupAddress TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the board LLAP address already exists
        in this chassis."
    ::= 11069

boardMailboxFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of a board mailbox failure."
    ::= 11070

boardMailboxOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the board mailbox is now OK."
    ::= 11071

psACHotTempShutdown TRAP-TYPE
    ENTERPRISE  cabletron 
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply is hot and the
        power supply has shut itself down."
    ::= 11072

psACWarmTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply is warm."
    ::= 11073

psACTempOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply has returned
        to normal after being warm or hot."
    ::= 11074

psACTempOKNoAdmin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply has returned 
        to normal after being shutdown remotely. It will need to be powerOn
        remotely."
    ::= 11075

psACTempSensorBroken TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the AC power supply's temperature
        sensor is broken."
    ::= 11076

psACTempHot TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply is hot."
    ::= 11077

psACInputVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply input voltage
        is over max."
    ::= 11078

psACInputVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply input voltage
        is under minimum."
    ::= 11079

psACInputVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply input voltage has
        returned to normal after being over or under."
    ::= 11080

psACSystemVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply system voltage is
        over MAX."
    ::= 11081

psACSystemVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply system voltage is
        under MIN."
    ::= 11082

psACSystemVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply system voltage has
        returned to normal after being over or under."
    ::= 11083

psACLogicVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic voltage is
        over MAX."
    ::= 11084

psACLogicVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic voltage is 
        under MIN."
    ::= 11085

psACLogicVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic voltage has
        returned to normal after being over or under."
    ::= 11086

psACTermVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term voltage is
        over MAX."
    ::= 11087

psACTermVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term voltage is 
        under MIN."
    ::= 11088

psACTermVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term voltage has
        returned to normal after being over or under."
    ::= 11089

psACLogicSenseCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11090

psACTermSenseCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11091

psACInputCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply input current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11092

psACSystemCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply system current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11093

psACLogicCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11094

psACTermCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term current is 
        over MAX. The power supply has therefore been shutdown."
    ::= 11095

psACLogicSenseCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic sense current 
        is over MAX. The power supply has therefore been shutdown."
    ::= 11096

psACTermSenseCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term sense current
        is over MAX. The power supply has therefore been shutdown."
    ::= 11097

psACInputCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply input current is 
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11098

psACSystemCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply system current is
        over MAX. The ability of the power supply to turn itself off has been
        disabled therefore outside intervention is needed."
    ::= 11099

psACLogicCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply logic current is
        over MAX. The ability of the power supply to turn itself off has been
        disabled therefore outside intervention is needed."
    ::= 11100

psACTermCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an AC power supply term current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11101

psACRemotePowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply is being powered
        off due to outside intervention."
    ::= 11102

psACSystemPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply system power has
        been powered on."
    ::= 11103

psACSystemPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply system power has
        been powered off."
    ::= 11104

psACLogicPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply logic power has
        been powered on."
    ::= 11105

psACLogicPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply logic power has
        been powered off."
    ::= 11106

psACTermPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply term power has
        been powered on."
    ::= 11107

psACTermPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply term power has
        been powered off."
    ::= 11108

psACRemOverCurrentShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply has been shutdown
        remotely due to being over current."
    ::= 11109

psACRemPowerConservationShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply has been shutdown
        remotely due to power conservation."
    ::= 11110

psACADConvertorFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply A/D converter
        is broken."
    ::= 11111

psACPICFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of an AC power supply PIC failure."
    ::= 11112

psACPICOk TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply PIC is now OK.
        This trap will only be sent AFTER a PIC failure trap has been
        generated."
    ::= 11113

psACLLAPDupAddress TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the AC power supply LLAP address already
        exists in this chassis."
    ::= 11114

psACFanFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of an AC power supply fan failure."
    ::= 11115

psACFanOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the AC power supply fan is now OK.
        This trap will only be sent AFTER a fan failure trap has been
        generated."
    ::= 11116

psDCHotTempShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply is hot and the
        power supply has shut itself down."
    ::= 11117

psDCWarmTemp TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply is warm."
    ::= 11118

psDCTempOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply has returned
        to normal after being warm or hot."
    ::= 11119

psDCTempOKNoAdmin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply has returned 
        to normal after being shutdown remotely. It will need to be powerOn
        remotely."
    ::= 11120

psDCTempSensorBroken TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the DC power supply's temperature
        sensor is broken."
    ::= 11121

psDCTempHot TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply is hot."
    ::= 11122

psDCInputVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply input voltage
        is over max."
    ::= 11123

psDCInputVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply input voltage
        is under minimum."
    ::= 11124

psDCInputVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply input voltage has
        returned to normal after being over or under."
    ::= 11125

psDCSystemVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply system voltage is
        over MAX."
    ::= 11126

psDCSystemVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply system voltage is
        under MIN."
    ::= 11127

psDCSystemVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply system voltage has
        returned to normal after being over or under."
    ::= 11128

psDCLogicVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic voltage is
        over MAX."
    ::= 11129

psDCLogicVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic voltage is 
        under MIN."
    ::= 11130

psDCLogicVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic voltage has
        returned to normal after being over or under."
    ::= 11131

psDCTermVoltageOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term voltage is
        over MAX."
    ::= 11132

psDCTermVoltageUnderMin TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term voltage is 
        under MIN."
    ::= 11133

psDCTermVoltageOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term voltage has
        returned to normal after being over or under."
    ::= 11134

psDCLogicSenseCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11135

psDCTermSenseCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11136

psDCInputCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply input current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11137

psDCSystemCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply system current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11138

psDCLogicCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic current is
        over MAX. The power supply has therefore been shutdown."
    ::= 11139

psDCTermCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term current is 
        over MAX. The power supply has therefore been shutdown."
    ::= 11140

psDCLogicSenseCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic sense current 
        is over MAX. The power supply has therefore been shutdown."
    ::= 11141

psDCTermSenseCurrentOverMaxShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term sense current
        is over MAX. The power supply has therefore been shutdown."
    ::= 11142

psDCInputCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply input current is 
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11143

psDCSystemCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply system current is
        over MAX. The ability of the power supply to turn itself off has been
        disabled therefore outside intervention is needed."
    ::= 11144

psDCLogicCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply logic current is
        over MAX. The ability of the power supply to turn itself off has been
        disabled therefore outside intervention is needed."
    ::= 11145

psDCTermCurrentOverMax TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because an DC power supply term current is
        over MAX. The ability of the power supply to turn itself off has been 
        disabled therefore outside intervention is needed."
    ::= 11146

psDCRemotePowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply is being powered
        off due to outside intervention."
    ::= 11147

psDCSystemPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply system power has
        been powered on."
    ::= 11148

psDCSystemPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply system power has
        been powered off."
    ::= 11149

psDCLogicPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply logic power has
        been powered on."
    ::= 11150

psDCLogicPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply logic power has
        been powered off."
    ::= 11151

psDCTermPowerOn TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply term power has
        been powered on."
    ::= 11152

psDCTermPowerOff TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply term power has
        been powered off."
    ::= 11153

psDCRemOverCurrentShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply has been shutdown
        remotely due to being over current."
    ::= 11154

psDCRemPowerConservationShutdown TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply has been shutdown
        remotely due to power conservation."
    ::= 11155

psDCADConvertorFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply A/D converter
        is broken."
    ::= 11156

psADPICFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of an DC power supply PIC failure."
    ::= 11157

psADPICOk TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply PIC is now OK.
        This trap will only be sent AFTER a PIC failure trap has been
        generated."
    ::= 11158

psADLLAPDupAddress TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when the DC power supply LLAP address already
        exists in this chassis."
    ::= 11159

psADFanFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because of an DC power supply fan failure."
    ::= 11160

psDCFanOK TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated because the DC power supply fan is now OK.
        This trap will only be sent AFTER a fan failure trap has been
        generated."
    ::= 11161

psADConvertorFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID }
    DESCRIPTION
        "This trap is generated because the power supply A/D converter
        is broken."
    ::= 11162

psPicFailure TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID }
    DESCRIPTION
        "This trap is generated because of a power supply PIC failure."
    ::= 11163

psPICok TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID }
    DESCRIPTION
        "This trap is generated because the power supply PIC is now OK.
        This trap will only be sent AFTER a PIC failure trap has been
        generated."
    ::= 11164

psLLAPDupAddress TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID }
    DESCRIPTION
        "This trap is generated when the power supply LLAP address already
        exists in this chassis."
    ::= 11165

chEnvAmbientTempChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { chEnvAmbientStatus, chEnvAmbientTemp }
    DESCRIPTION
        "This trap is generated for each and every time the chassis
         ambient temperature crosses over a threshold value
         of either one of the chassis set thresholds chEnvAmbientHot,
         chEnvAmbientWarm, chEnvAmbientCool, or chEnvAmbientCold
         to another. This trap is also sent when the chassis temperature
         sensor is detected to be broken or not supported."
    ::= 11166

chEnvHumidityChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { chEnvHumidityStatus, chEnvHumidity }
    DESCRIPTION
        "This trap is generated for each and every time the chassis
         humidity crosses a threshold value of either chEnvHumidityMoist,
         or chEnvHumidityDry, or when the humidity sensor is detected to
         be broken or not supported."
    ::= 11167

boardEnvTempChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardEnvSlotID, boardEnvTemp, boardEnvTempStatus }
    DESCRIPTION
        "This trap is generated for each and every time the board
         temperature crosses over a threshold value of either
         one of the board set thresholds boardEnvTempHot,
         boardEnvTempWarm, boardEnvTempCool, or boardEnvTempCold
         to another. This trap is also sent when the board temperature
         sensor is detected to be broken or not supported."
    ::= 11168

boardEnvTempRelChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardEnvSlotID, boardEnvTempRelStatus, 
                boardEnvTemp, chEnvAmbientTemp }
    DESCRIPTION
        "This trap is generated for each and every time the board
         temperature relative to the chassis ambient temperature
         crosses a threshold value of either boardEnvTempRelHot,
         or boardEnvTempRelWarm. This trap is also sent when either
         temperature sensor located on the board or on the chassis
         is detected to be broken or not supported."
    ::= 11169

boardEnvTempMaxFanRelChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardEnvSlotID, boardEnvTempRelStatus, 
                boardEnvTemp, chEnvAmbientTemp }
    DESCRIPTION
        "This trap is generated for each and every time the board
         temperature relative to the chassis ambient temperature
         crosses a threshold value of either boardEnvTempMaxFanRelHot,
         or boardEnvTempMaxFanRelWarm when all fans in the chassis are
         operating at there maximum speed. This trap is also sent when
         either temperature sensor located on the board or on the chassis
         is detected to be broken or not supported."
    ::= 11170

chPowerMainVoltageChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { chPowerMainVoltageStatus, chPowerMainVoltage }
    DESCRIPTION
        "This trap is generated for each and every time the chassis
         main voltage rail deviates and causes the chPowerMainVoltageStatus
         to switch state from powerOK(1), overCurrent(2), overVoltage(3),
       or underVoltage(4) to another."
    ::= 11171

chPowerDiagVoltageChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { chPowerDiagVoltageStatus, chPowerDiagVoltage }
    DESCRIPTION
        "This trap is generated for each and every time the chassis
         diag voltage deviates and causes the chPowerDiagVoltageStatus
         to switch state from powerOK(1), overCurrent(2), overVoltage(3),
         or underVoltage(4) to another."
    ::= 11172

termPowerVoltageChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { termPowerStatus, termPowerVoltage }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         termination unit changes state and causes the termPowerStatus
         to switch from any states to either powerOK(1), overVoltage(3), or
         underVolatge(4) state."
    ::= 11173

boardPowerVoltageChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotID, boardPowerID,
                boardPowerStatus, boardPowerVoltage }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         power line voltage deviates and causes the boardPowerStatus
         to switch from any states to either powerOK(1), overVoltage(4),
         or underVoltage(5) state."
    ::= 11174

termPowerModule1Changes TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { termPowerModule1Status  }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         front panel button changes state and causes the termPowerModule1Status
         to switch state from either one of normal(1), iNBaFault(2),
         iNBbFault(3), fault(4), termModuleNotInstalled(5) to another."
    ::= 11175

termPowerModule2Changes TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { termPowerModule2Status  }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         front panel button changes state and causes the termPowerModule2Status
         to switch state from either one of normal(1), iNBaFault(2),
         iNBbFault(3), fault(4), termModuleNotInstalled(5) to another."
    ::= 11176

chEnvFanChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { chEnvFanID, chEnvFanStatus, chEnvFanSpeed }
    DESCRIPTION
        "This trap is generated for each and every time the chassis
         fan changes over its status from either one value unknown(1),
         normal(2), testing(3), slow(4), inoperative(5), or off(6)
         to another."
    ::= 11177

boardPowerCurrentChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotID, boardPowerID,
                boardPowerStatus, boardPowerCurrent }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         power line current deviates and causes the boardPowerStatus
         to switch from any states to powerOK(1), or overCurrent(3) state."
    ::= 11182

boardPowerFrontPanelChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID, boardPowerLocalAdminStatus, 
                boardPowerLocalStatus }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         front panel button state changes, it is caused when the
         boardPowerLocalStatus switching state from either one
         of resetRequest(1), powerDownRequest(2), powerOnRequest(3),
         or normal(4) to another."
    ::= 11183

boardPowerOperationalChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { boardPowerSlotStatusID, boardPowerOperationalStatus }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         DC-DC converter power supply voltage deviates and causes the
         boardPowerOperationalStatus to switch state from powerOn(1),
         powerOff(2), reset(3), overVoltage(4), underVoltage(5),
         overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8),
         remotePowerOff(9), powerConservationShutdown(10), or
         frontPanelPowerOff(11) to another."
    ::= 11184

psEnvTempChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES {  psEnvSlotID, psEnvTempStatus, psEnvTemp }
    DESCRIPTION
        "This trap is generated for each and every time the power
         supply temperature crosses over a threshold value of either
         one of the power supply set thresholds psEnvTempHot,
         psEnvTempWarm, psEnvTempCool, or psEnvTempCold to another.
         This trap is also sent when the power supply temperature
         sensor is detected to be broken or not supported."
    ::= 11185

psEnvFanChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psEnvSlotID, psEnvFanStatus, psEnvFanSpeed }
    DESCRIPTION
        "This trap is generated for each and every time the power
         supply fan changes over its status from either one value
         unknown(1), normal(2), testing(3), slow(4), inoperative(5),
         or off(6) to another."
    ::= 11186

psPowerVoltageChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID, psPowerID,
                psPowerStatus, psPowerVoltage }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         power line voltage deviates and causes the psPowerStatus
         to switch from any states to either powerOK(1), overVoltage(4),
         or underVoltage(5) state."
    ::= 11187

psPowerCurrentChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID, psPowerID,
                psPowerStatus, psPowerCurrent }
    DESCRIPTION
        "This trap is generated for each and every time the module's
         power line current deviates and causes the psPowerStatus
         to switch from any states to powerOK(1), or overCurrent(3) state."
    ::= 11188

psPowerAdminChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES { psPowerSlotID, psPowerID, psPowerAdmin }
    DESCRIPTION
        "This trap is generated for each and every time the power
         supply power line changes state from one operational mode
         to another switching between powerOn(1) and powerOff(2)."
    ::= 11189

psPowerOperationalChanges TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES {  psPowerSlotStatusID, psPowerOperationalStatus}
    DESCRIPTION
        "This trap is generated for each and every time the module's
         DC-DC converter power supply voltage deviates and causes the
         psPowerOperationalStatus to switch state from either one
         of powerOn(1), powerOff(2), reset(3), overVoltage(4),
         underVoltage(5), overCurrent(6), overCurrentShutdown(7),
         temperatureShutdown(8), or remotePowerOff(9) to another."
    ::= 11190

boardInserted TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus card
         is inserted in the chassis."
    ::= 11191 

boardRemoved TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { boardPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus card
         is removed from the chassis."
    ::= 11192 

psInserted TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus power supply
         is inserted in the chassis."
    ::= 11193 

psRemoved TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus power supply
         is removed from the chassis."
    ::= 11194 

psRedundant TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus power supply
        has a redundant power supply"
    ::= 11195

psNotRedundant TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { chPowerLineMaxSupply, chPowerLineTotalSupply }
    DESCRIPTION
        "This trap is generated when an MMACplus power supply
        has no redundant power supply"
    ::= 11196

psNormal TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus board is
        transitioning to a normal state from a fault state"
    ::= 11197

psFault TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { psPowerSlotStatusID }
    DESCRIPTION
        "This trap is generated when an MMACplus power supply
        is not operational"
    ::= 11198

upsLineFail  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated in the event of an AC utility
         line failure."
    ::= 11200

upsLineFailRecovery  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated when the UPS switches back
         to line, and only if the upsLineFail trap was issued
         first."
    ::= 11201

upsLowBattery  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated in the event that the UPS's
         battery is found to be low."
    ::= 11202

upsLowBatteryRecovery  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated when the UPS's battery has
         charged above the low-battery point, and only if the
         upsLowBattery trap was issued first."
    ::= 11203

upsAbnormalCondition  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex, upsStatusFault, upsAddlFuncsStatusFault }
    DESCRIPTION
        "This trap is generated in the event that the UPS
         has entered an abnormal condition, such as an
         overload or trip on low battery.  This trap is also
         sent when the UPS is first turned on."
    ::= 11204

upsAbnormalConditionRecovery  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated when the UPS has recovered
         from an abnormal condition, and only if the
         upsAbnormalCondition trap was issued first."
    ::= 11205

upsShuttingDown  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated in the event that the UPS
         has been ordered to shut itself, or the load, off
         over the serial line."
    ::= 11206

upsReplaceBattery  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex }
    DESCRIPTION
        "This trap is generated when the UPS's battery test
         has determined that a UPS battery is unable to retain
         adequate charge.  This trap will be generated every
         five hours until a new battery test is run or the
         UPS is turned off."
    ::= 11207

upsExtMeasAlarm  TRAP-TYPE
    ENTERPRISE  cabletron
    VARIABLES  { upsIndex, upsExtMeasAlarmStatus }
    DESCRIPTION
        "This trap is generated when the External Measurement Unit
         has detected that an ambient temperature or humidity limit
         extreme has been exceeded, or that one of the contact closure
         inputs has changed from the selected `normal' state.  In
         the case of multiple alarms, a trap is generated for every
         alarm condition detected.  In addition, the trap is sent
         every two minutes whenever an alarm condition exists.  It
         is discontinued when all alarm conditions are reset.  This
         trap is sent only for alarm states that have been enabled."
    ::= 11208

nvmpUdefTrap  TRAP-TYPE
    ENTERPRISE cabletron
    DESCRIPTION
        "This trap is generated when a new NVMP trap is sent that
        does not have an SNMP counterpart."
    ::= 11999

--
-- ================================================================
-- Trap values from 12000 - 12500 are reserved for ATM specific traps.
--

activePortInATMRedundancyFailed TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { ctATMPhyRedundIfIndex }
    DESCRIPTION
         "This trap will be generated when the active port, on a physical ATM
          interface that has redundancy enabled, has failed (become quiet)."
    ::= 12000
           
aTMRedundantPortActivated TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { ctATMPhyRedundIfIndex }
    DESCRIPTION
         "This trap indicates that a new port has been activated on a 
          physical ATM interface that has redundancy enabled.  This does 
          not indicate that this port is usable, but that it is being 
          tested as a possible replacement."
    ::= 12001

aTMRedundanctPortTestFailed TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { ctATMPhyRedundIfIndex }
    DESCRIPTION
         "This trap will be generated when the phyRedundIfTestTOD or the
          phyRedundIfPerformTest has tested a port and determined that it
          is not usable.  The port should be fixed prior to it being needed."
    ::= 12002

aTMRedundPrimaryPortSkipped TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { ctATMPhyRedundIfIndex }
    DESCRIPTION
         "This trap will be generated when redundancy finds that the primary
          port as designated be PhyRedundIfPrimaryPort is usable but cannot be
          used because PhyRedundIfPrimaryRevert is set to manual (2).  This
          trap is generated only when redundancy is enabled (PhyRedundIfStatus 
          is enable (1)) and the active port fails."
    ::= 12003

--atmHostAddressRegister TRAP-TYPE
--    ENTERPRISE cabletron
--    VARIABLES { atmIfAdminAddrRowStatus }
--    DESCRIPTION
--      "This trap signifies that the agent has detected
--       an atm address registration on a port."
--    ::= 12004 

-- atmHostAddressDeRegister TRAP-TYPE
--    ENTERPRISE cabletron
--    VARIABLES  { atmIfAdminAddrRowStatus }
--    DESCRIPTION
--      "This trap signifies that the agent has detected
--       an atm address deregistration on a port."
--    ::= 12005

atmCTMUp TRAP-TYPE
    ENTERPRISE cabletron
    DESCRIPTION
      "This trap signifies that the agent has detected
       the CTM operational. Connection set maps are allowed
       through the switch"
    ::= 12006

atmCTMDown TRAP-TYPE
    ENTERPRISE cabletron
    DESCRIPTION
      "This trap signifies that the agent has detected
       the CTM unoperational. A list of Cross Connect Ids
       will be sent indicating connections that need to be removed."
    ::= 12007

atmVcCrossConnectOperChange TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { atmVcCrossConnectRowStatus }
    DESCRIPTION
      "This trap signifies that the agent has detected
       a change in the operational status to down. A list of VC cross
       connections will be sent to be remapped."
    ::= 12008

atmVpCrossConnectOperChange TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { atmVpCrossConnectRowStatus }
    DESCRIPTION
      "This trap signifies that the agent has detected
       a change in the operational status to down. A list of VP cross
       connections will be sent to be remapped."
   ::= 12009

atmNeighborSwitchUp TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { atmInterfaceMyNeighborIpAddress,
                atmInterfaceMyNeighborIfName }
    DESCRIPTION
      "This trap signifies that the agent has detected
       a neighbor switch on a port."
    ::= 12010

atmNeighborSwitchDown TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES  { atmInterfaceMyNeighborIpAddress,
                 atmInterfaceMyNeighborIfName }
    DESCRIPTION
      "This trap signifies that the agent has detected
       a lost neighbor switch on a port."
    ::= 12011

callFailure TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex }
     DESCRIPTION
       "SPVC Call Failures."
     ::= 12012

allocBwHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Allocated bandwidth for this port has exceeded the 
        allocBwThresholdHiFwd."
     ::= 12013

allocBwHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Allocated bandwidth for this port has exceeded the
       allocBwThresholdHiRev."
     ::= 12014

allocBwLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Allocated bandwidth for this port is below the 
        allocBwThresholdLoFwd."
     ::= 12015

allocBwLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Allocated bandwidth for this port is below the 
        allocBwThresholdLoRev."
     ::= 12016

aggPcrFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "The total of all the aggregate peak cell rates for the VCs using 
        this port exceeds the physical bandwidth of the port in the forward 
        direction."
     ::= 12017

aggPcrRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "The total of all the aggregate peak cell rates for the VCs using 
        this port exceeds the physical bandwidth of the port in the reverse
        direction."
     ::= 12018

peakFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "The peak allocated bandwidth has exceeded the peakBwTholdFwd
        value."
     ::= 12019

peakRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "The peak allocated bandwidth has exceeded the peakBwTholdRev
        value."
     ::= 12020

cbrConnCountTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active constant bit rate connections exceeding
        the CBRConnectionCountTholdHiFwd threshold."
     ::= 12021

cbrConnCountTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active CBR connections exceeding the 
        CBRConnectionCountTholdHiRev threshold."
     ::= 12022

cbrConnCountTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active CBR connections exceeding the 
        CBRConnectionCountTholdLoFwd threshold."
     ::= 12023

cbrConnCountTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active CBR connections exceeding the 
        CBRConnectionCountTholdLoRev threshold."
     ::= 12024

cbrAllocBwTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which CBR exceeds the 
        CBRAllocatedBwTholdHiFwd threshold."
     ::= 12025

cbrAllocBwTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which CBR exceeds the 
        CBRAllocatedBwTholdHiRev threshold."
     ::= 12026

cbrAllocBwTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which CBR exceeds the 
        CBRAllocatedBwTholdLoFwd threshold."
      ::= 12027

cbrAllocBwTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which CBR exceeds the 
        CBRAllocatedBwTholdLoRev threshold."
     ::= 12028

vbrConnCountTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active variable bit rate connections exceeding 
       the VBRConnectionCountTholdHiFwd threshold."
     ::= 12029

vbrConnCountTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active VBR connections exceeding the
       VBRConnectionCountTholdHiRev threshold."
     ::= 12030

vbrConnCountTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active VBR connections exceeding the
       VBRConnectionCountTholdLoFwd threshold."
     ::= 12031

vbrConnCountTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active VBR connections exceeding the
       VBRConnectionCountTholdLoRev threshold."
     ::= 12032

vbrAllocBwTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which VBR exceeds the
        VBRAllocatedBwTholdHiFwd threshold."
     ::= 12033

vbrAllocBwTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which VBR exceeds the
        VBRAllocatedBwTholdHiRev threshold."
     ::= 12034

vbrAllocBwTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which VBR exceeds the
        VBRAllocatedBwTholdLoFwd threshold."
     ::= 12035

vbrAllocBwTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which VBR exceeds the
        VBRAllocatedBwTholdLoRev threshold."
     ::= 12036

abrConnCountTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active available bit rate connections 
        exceeding the ABRConnectionCountTholdHiFwd threshold."
     ::= 12037

abrConnCountTholdHiRev  TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active ABR connections exceeding the 
        ABRConnectionCountTholdHiRev threshold."
     ::= 12038

abrConnCountTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active ABR connections exceeding the 
        ABRConnectionCountTholdLoFwd threshold."
     ::= 12039

abrConnCountTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active ABR connections exceeding the 
        ABRConnectionCountTholdLoRev threshold."
     ::= 12040

abrAllocBwTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which ABR exceeds the
        ABRAllocatedBwTholdHiFwd threshold."
     ::= 12041

abrAllocBwTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which ABR exceeds the
        ABRAllocatedBwTholdHiRev threshold."
     ::= 12042

abrAllocBwTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which ABR exceeds the
        ABRAllocatedBwTholdLoFwd threshold."
     ::= 12043

abrAllocBwTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which ABR exceeds the
        ABRAllocatedBwTholdLoRev threshold."
     ::= 12044

ubrConnCountTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active unavailable bit rate connections 
        exceeding the UBRConnectionCountTholdHiFwd threshold."
     ::= 12045

ubrConnCountTholdHiRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active UBR connections exceeding the 
        UBRConnectionCountTholdHiRev threshold."
     ::= 12046

ubrConnCountTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active UBR connections exceeding the 
        UBRConnectionCountTholdLoFwd threshold."
     ::= 12047

ubrConnCountTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Count of currently active UBR connections exceeding the 
        UBRConnectionCountTholdLoRev threshold."
     ::= 12048

ubrAllocBwTholdHiFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which UBR exceeds the
        UBRAllocatedBwTholdHiFwd threshold."
     ::= 12049

-- 12050 is ATM services specific...see below

ubrAllocBwTholdLoFwd TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which UBR exceeds the
        UBRAllocatedBwTholdLoFwd threshold."
     ::= 12051

ubrAllocBwTholdLoRev TRAP-TYPE
     ENTERPRISE cabletron
     VARIABLES { ifIndex } 
     DESCRIPTION
       "Bandwidth currently allocated which UBR exceeds the
        UBRAllocatedBwTholdLoRev threshold."
     ::= 12052


ubrAllocBwTholdHiRev TRAP-TYPE
  ENTERPRISE cabletron
  VARIABLES { ifIndex }
  DESCRIPTION
    "Bandwidth currently allocated which UBR exceeds the
     UBRAllocatedBwTholdHiRev threshold."
   ::= 12053

--Values 12010-12050 reserved for future ATM traps. 

atmLecStatus TRAP-TYPE
    ENTERPRISE cabletron
    VARIABLES { lecRowStatus }
    DESCRIPTION
        "This trap is generated when the operational
        state of the LAN Emulation Client has changed."
    ::= 12050

--Values 13000-13001 reserved for future ATM traps. 

boardOperational TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID, deviceType }
        DESCRIPTION
            "This trap will be generated when an entity detects
             that a module has become operational."
        ::= 13000

boardNonOperational TRAP-TYPE
        ENTERPRISE cabletron
        VARIABLES { chSlotID }
        DESCRIPTION
            "This trap will be generated when an entity detects
             that a module is no longer operational."
        ::= 13001

END